{"id":7464,"date":"2023-01-21T19:54:15","date_gmt":"2023-01-21T10:54:15","guid":{"rendered":"http:\/\/protec5461.co.jp\/protec\/?p=7464"},"modified":"2023-01-21T19:54:15","modified_gmt":"2023-01-21T10:54:15","slug":"%e5%8c%bb%e7%99%82%e7%94%a8%e3%82%b3%e3%83%8d%e3%82%af%e3%82%bf%e8%a9%a6%e9%a8%93%e6%a9%9f%e3%80%80pt-1945s","status":"publish","type":"post","link":"http:\/\/protec5461.co.jp\/protec\/?p=7464&lang=en","title":{"rendered":"Medical connector measurement system &#8220;PT-1946MC&#8221;"},"content":{"rendered":"<b>Outline<\/b><br>\r\n&#8220;PT-1946MC&#8221; can perform fitting and torsion stress test specified in common test method of former ISO 594 and ISO 80369 Part 20.<br>\r\nFitting and torsion stress test is performed by fixing the fitting gauge on the driving unit side and the medical connector on the torque sensor side and twisting while pressing the fitting gauge and the medical connector. Pressing is done by the electro-pneumatic regulator and the pressing load value is measured by the load cell. Torsion is done by the drive unit and the torsion torque is measured with the torque sensor.<br>\r\n<br>\r\n<div class=\"scroll-box\"><table>\r\n<tr>\r\n<td align=\"center\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/protec5461.co.jp\/protec\/wp-content\/uploads\/2017\/03\/20a25eae874fd701a16022b23d3d742d.png\" alt=\"PT-1946MC\" width=\"580\" height=\"320\"><br><br>Medical connector measurement system &#8220;PT-1946MC&#8221;<\/td>\r\n<\/tr>\r\n<\/table><\/div>\r\n<br>\r\n<br>\r\n<br>\r\n\r\n\r\n<b>Configuration<\/b><br>\r\n<br>\r\n<div class=\"scroll-box\"><table>\r\n<tr>\r\n<td align=\"center\">\r\n<img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/protec5461.co.jp\/protec\/wp-content\/uploads\/2018\/09\/49ec4da8dd6c3e069f1221e46bfa00ee.jpg\" alt=\"PT-1946MC_Configuration\" width=\"650\" height=\"290\"><\/td>\r\n<\/tr>\r\n<\/table><\/div>\r\n<br>\r\n<div class=\"scroll-box\"><table>\r\n<tr>\r\n<td align=\"center\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/protec5461.co.jp\/protec\/wp-content\/uploads\/2017\/03\/94cfd184b92f12aae4d338f7a0ecda88.jpg\" alt=\"Before the test\r\n\" width=\"250\" height=\"175\" ><br \/>Before the test<\/td>\r\n<td width=\"10\"><\/td>\r\n<td align=\"center\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/protec5461.co.jp\/protec\/wp-content\/uploads\/2017\/03\/88f0d2affc95bd5da1e6bb381fa7c712.jpg\" alt=\"During the test\r\n\" width=\"250\" height=\"175\"><br>During the test<\/td>\r\n<\/tr>\r\n<\/table><\/div>\r\n<br>\r\n<br>\r\n\r\n\r\n\r\n<b>Feature<\/b><br>\r\n<strong>\u25cf&#8221;PT-1946MC&#8221; can perform fitting and torsion stress test specified in common test method of former ISO 594 and ISO 80369 Part 20. <\/strong><br>\r\n\u30fbfitting and torsion stress test specified of ISO80369-3 and  ISO8039-6 , ISO80369-7<br>\r\n\u30fbISO80369-20:Common test methods<br>\r\n\u30fbformer ISO 594<br>\r\n<br>\r\n\r\n<strong>\u25cfPanel screen.<\/strong><br>\r\nA panel screen is provided on the screen of the computer to display torque, load and angle.<br>\r\n<br>\r\n<img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/protec5461.co.jp\/protec\/wp-content\/uploads\/2017\/03\/1582c0169116e1c47c78d78c2155eaf0.jpg\" alt=\"ISO80369_Panel screen\" width=\"180\" height=\"120\"><br>\r\n<br>\r\n\r\n<strong>\u25cfGraph screen.<\/strong><br>\r\nTorque, load, angle curve is displayed.<br>\r\nSampling is performed at specified time intervals.<br>\r\n<br>\r\n<img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/protec5461.co.jp\/protec\/wp-content\/uploads\/2016\/09\/e99cc3808964d9e08ec8fb27d43842de-300x166.png\" alt=\"ISO80369_Graph screen\" width=\"180\" height=\"120\" ><br>\r\n<br>\r\n\r\n<strong>\u25cfSave measurement data as CSV file in text format.<\/strong><br>\r\n<br>\r\n\r\n<strong>\u25cfCompact and lightweight.<\/strong><br>\r\n<br>\r\n\r\n<strong>\u25cfHandy handle is attached for easy carrying.<\/strong><br>\r\n<br>\r\n<img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/protec5461.co.jp\/protec\/wp-content\/uploads\/2016\/09\/P9243964-1024x709.jpg\" width=\"180\" height=\"120\"><br>\r\n<br>\r\n<br>\r\n<br>\r\n\r\n<b>Specification<\/b><br>\r\n<strong>Torque sensor\u30001Nm<\/strong>\r\n<div class=\"scroll-box\"><table class=\"products_table\">\r\n<tr><th class=\"c_center\">Torque resolution<\/th><td>1mNm<\/th><\/tr>\r\n<tr><th class=\"c_center\">Total torque accuracy<\/th><td>\u00b11%\u00b13Digit<\/td><\/tr>\r\n<\/table><\/div>\r\n<br>\r\n<strong>Lord cell\u3000100N<\/strong>\r\n<div class=\"scroll-box\"><table class=\"products_table\">\r\n<tr><th class=\"c_center\">Load resolution<\/th><td>0.1N<\/th><\/tr>\r\n<tr><th class=\"c_center\">Load Accuracy<\/th><td>\u00b11%\u00b13Digit<\/td><\/tr>\r\n<\/table><\/div>\r\n<br>\r\n<br>\r\n<br>\r\n\r\n<b>Option<\/b><br>\r\nA reference connector is required to perform tests conforming to ISO 80369 and former ISO 594 using this device.It is possible to prepare an optional jig for connecting this unit to the reference connector.<br>\r\n<u>\u203bNo reference connector is attached to this.Please purchase separately.<\/u><br>\r\n<br>\r\n\u226aJig Production Example\u226b<br>\r\n<br>\r\n<div class=\"scroll-box\"><table>\r\n<tr>\r\n<td align=\"center\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/protec5461.co.jp\/protec\/wp-content\/uploads\/2016\/11\/Fig5.jpg\" alt=\"ISO80369_JIG\" width=\"320\" height=\"240\"><br>Former ISO594-2\u3000Fig.5<\/td>\r\n<td width=\"10\"><\/td>\r\n<td align=\"center\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/protec5461.co.jp\/protec\/wp-content\/uploads\/2016\/11\/Fig6.jpg\" alt=\"ISO80369_JIG\" width=\"320\" height=\"230\"><br>Former ISO594-2\u3000Fig.6<\/td>\r\n<\/tr>\r\n<\/table><\/div>\r\n<br>\r\n<div class=\"scroll-box\"><table>\r\n<tr>\r\n<td align=\"center\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/protec5461.co.jp\/protec\/wp-content\/uploads\/2016\/11\/Fig7.8.jpg\" alt=\"ISO80369_JIG\" width=\"320\" height=\"240\"><br>Former ISO594-2\u3000Fig.7.8<\/td>\r\n<\/tr>\r\n<\/table><\/div>\r\n<br>\r\n<br>\r\n<br>\r\n\r\n<a name=\"a\"><\/a>\r\n<b>Corresponding test item<\/b><br>\r\nItems in red can be tested with this unit.<br>\r\n<u>\u203bLeak test is not supported.<\/u><br>\r\n<br>\r\n<strong>ISO80369<br>Small-bore connectors for liquids and gases in healthcare applications.<br>\r\nPart20:Common test methods.<strong><br>\r\n<div class=\"scroll-box\"><table class=\"products_table\">\r\n<tr><th rowspan=\"2\" class=\"c_center\">TEST METHOD<\/th><th colspan=\"2\" class=\"c_center\">TEST METHOD<\/th><\/tr>\r\n<tr><th class=\"c_center\">FITTING<\/th><th class=\"c_center\">TEST<\/th><\/tr>\r\n<tr><th class=\"c_center\">Annex B<br>Leakage by pressure<br>decay TEST METHOD<br><\/th><td rowspan=\"9\" class=\"c_center\"><font color=red>Axial force:26.5N\uff5e27.5N<br>Torque:0.08Nm\uff5e0.12N<br>Time:5s\uff5e6s<\/td><td class=\"c_center\">\uff08Abridgement\uff09<\/font><\/td><\/tr>\r\n<tr><th class=\"c_center\">Annex C<br>Falling drop positive-pressure<br>liquid leakage TEST METHOD<\/th><td class=\"c_center\">\uff08Abridgement\uff09<\/td><\/tr>\r\n<tr><th class=\"c_center\">Annex D<br>Subatmospheric-pressure air<br>leakage TEST METHOD<\/th><td class=\"c_center\">\uff08Abridgement\uff09<\/td><\/tr>\r\n<tr><th class=\"c_center\">Annex E<br>Stress cracking TEST METHOD<\/th><td class=\"c_center\">\uff08Abridgement\uff09<\/td><\/tr>\r\n<tr><th class=\"c_center\">Annex F<br>Resistance to separation from<br>axial load TEST METHOD<\/th><td class=\"c_center\"><font color=red>Hold the axial force for the hold<br>period from the relevant<br>APLICATION part of ISO80369.<\/font><\/td><\/tr>\r\n<tr><th class=\"c_center\">Annex G<br>Resistance to separation<br>from unscrewing TEST METHOD<\/th><td class=\"c_center\"><font color=red>Apply an unscrewing torque <br>to the collar as specified<br> in the relevant APPLICATION<br>part of ISO80369.<\/font><\/td><tr>\r\n<tr><th class=\"c_center\">Annex H<br>Resistance to overriding<br>TEST METHOD<\/th><td class=\"c_center\"><font color=red>Apply the torque specified<br>in the relevant <br>APPLICATION part of<br>ISO80369 to the CONNECTOR<br>under test.<\/font><\/td><\/tr>\r\n<tr><th class=\"c_center\">Annex I<br>Disconnection by unscrewing<br>TEST METHOD<\/th><td class=\"c_center\"><font color=red>Apply an unscrewing torque<br>to the CONNECTOR under<br>test at a rate of<br>approximately 2 r\/min until<br>the CONNECTION separates.<\/font><\/td><\/tr>\r\n<\/table><\/div>\r\n\u203bPlease refer to ISO 80369-20, ISO 80369-3, ISO 80369-6, ISO 80369-7 for details of the test.<br>\r\n<br>\r\n<br>\r\n\r\n<strong>Former ISO594<br>Conical fitting with a 6%(Luer) taper for syringes,needles and certain other medical equipment.\r\n<br>\r\nPart1:General requirements<\/strong><br>\r\n<div class=\"scroll-box\"><table class=\"products_table\">\r\n<tr><th rowspan=\"2\" class=\"c_center\">4.Requirements<\/th><th colspan=\"2\" class=\"c_center\">5.TEST METHOD<\/th><\/tr>\r\n<tr><th class=\"c_center\">FITTING<\/th><th class=\"c_center\">TEST<\/th><\/tr>\r\n<tr><th class=\"c_center\">4.1<br>Dimensions<\/th><td class=\"c_center\">&#8211;<\/td><td class=\"c_center\">5.1.4<br>Axial force:5N<\/tr>\r\n<tr><th class=\"c_center\">4.2<br>Liquid  leakage<\/th><td rowspan=\"4\" class=\"c_center\"><font color=red>5.2.1\u30005.3.1.1\u30005.5.1<br>Torque:<br>Not exceeting 0.1Nm<br>Rotation:<br>Not exceeting 90\u00b0<br>Axial force:<br>27.5N<br>Time:<br>5s<\/td><td class=\"c_center\">5.2.3<br>\uff08Abridgement\uff09<\/font><\/td><\/tr>\r\n<tr><th class=\"c_center\">4.3<br>Air leakage<\/th><td class=\"c_center\">5.3.1.2\uff5e5.1.7<br>\uff08Abridgement\uff09<\/td><\/tr>\r\n<tr><th class=\"c_center\">4.4<br>Separation force<\/th><td class=\"c_center\">5.4.2<br>\uff08Abridgement\uff09<\/td><\/tr>\r\n<tr><th class=\"c_center\">4.5<br>Stress cracking<\/th><td class=\"c_center\">5.5.2\u30005.5.3<br>\uff08Abridgement\uff09<\/td><\/tr>\r\n<\/table><\/div>\r\n\u203bPlease refer to former ISO594 for details of the test.<br>\r\n<br>\r\n<br>\r\n\r\n<strong>Former ISO594<br>Conical fitting with a 6%(Luer) taper for syringes,needles and certain other medical equipment.<br>\r\nPart2:Lock fitting<\/strong><br>\r\n<div class=\"scroll-box\"><table class=\"products_table\">\r\n<tr><th rowspan=\"2\" class=\"c_center\">4.Requirements<\/th><th colspan=\"2\" class=\"c_center\">TEST METHOD<\/th><\/tr>\r\n<tr><th class=\"c_center\">FITTING<\/th><th class=\"c_center\">TEST<\/th><\/tr>\r\n<tr><th class=\"c_center\">4.1<br>Gauging<\/th><td rowspan=\"2\" class=\"c_center\">&#8211;<\/td><td class=\"c_center\">5.1<br>\uff08Abridgement\uff09<br><\/tr>\r\n<tr><th class=\"c_center\">4.5<br>Ease of assembly<\/th><td class=\"c_center\">\uff08Abridgement\uff09<\/td><\/tr>\r\n<tr><th class=\"c_center\">4.2.1<br>Liquid leakage<\/th><td rowspan=\"5\" class=\"c_center\"><font color=red>5.2.1<br>Torque:<br>Not exceeting 0.12Nm<br>Axial force:<br>Not exceeting 27.5N<\/font><\/td><td class=\"c_center\">5.2.3<br>\uff08Abridgement\uff09<\/td><\/tr>\r\n<tr><th class=\"c_center\">4.2.2<br>Air leakage<\/th><td class=\"c_center\">5.3.2\u30005.3.3<br>\uff08Abridgement\uff09<\/td><\/tr>\r\n<tr><th class=\"c_center\">4.3<br>Separation force<\/th><td class=\"c_center\">5.4.2<br><font color=red>Axial force:<br>Not exceeting 35N<br>Time:<br>not less than 10s<\/font><\/td><\/tr>\r\n<tr><th class=\"c_center\">4.4<br>Unscrewing torque<\/th><td class=\"c_center\"><font color=red>5.5.2<\/font><br><font color=red>Unscrewing torque:0.02Nm<br>Time:\r\nNor less than 10s<\/font><\/td><\/tr>\r\n<tr><th class=\"c_center\">4.6<br>Resistance to overriding<\/th><td class=\"c_center\"><font color=red>5.7<br>Torque:Not less than 0.15Nm<br>Time:5s<\/font><\/td><\/tr>\r\n<tr><th class=\"c_center\">4.7<br>Stress cracking<\/th><td class=\"c_center\"><font color=red>5.8.1<br>Torque:<br>Not less than 0.12Nm<br>Axial force:<br>Not less than 27.5N<br>Time:5s<\/font><\/td><td class=\"c_center\">5.8.2<br>\uff08Abridgement\uff09<\/td><\/tr>\r\n<\/table><\/div>\r\n\u203bPlease refer to former ISO594 for details of the test.<br>\r\n<br>\r\n<br>\r\n<br>\r\n\r\n<b>Measurement data example<\/b><br>\r\n<strong>FITTING<br>\r\nISO80369-20<\/strong><br>\r\n<br>\r\n<img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/protec5461.co.jp\/protec\/wp-content\/uploads\/2017\/03\/3f5b653f09d8af5c4d1b41e9dd090778.jpg\" alt=\"ISO80369-20_FITTING\" width=\"220\" height=\"90\"><br>\r\n<br>\r\n<img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/protec5461.co.jp\/protec\/wp-content\/uploads\/2017\/03\/ISO80369-20_fitting.jpg\" alt=\"ISO80369_FITTING\" width=\"590\" height=\"300\">\r\n<br>\r\n<br><br>\r\n\r\n<strong>Resistance to separation from unscrewing TEST METHOD<br>\r\nISO80369-20 Annex G<\/strong><br>\r\n<br>\r\n<img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/protec5461.co.jp\/protec\/wp-content\/uploads\/2017\/03\/43598a5e72ce74f2f15047578ae12de3.jpg\" alt=\"ISO80369-20_Resistance to separation from unscrewing TEST METHOD\" width=\"200\" height=\"90\">\r\n<br><br>\r\n<img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/protec5461.co.jp\/protec\/wp-content\/uploads\/2017\/03\/ISO80369-20_unscrewing.jpg\" alt=\"ISO80369-20_Resistance to separation from unscrewing TEST METHOD\" width=\"580\" height=\"300\">\r\n<br>\r\n<br><br>\r\n\r\n<strong>Resistance to overriding TEST METHOD<br>\r\nISO80369-20 Annex H<\/strong><br>\r\n<br>\r\n<img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/protec5461.co.jp\/protec\/wp-content\/uploads\/2017\/03\/ab3d11c958504efad30d20b296f6c91e.jpg\" alt=\"ISO80369_Resistance to overriding TEST METHOD\" width=\"170\" height=\"90\">\r\n<br><br>\r\n<img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/protec5461.co.jp\/protec\/wp-content\/uploads\/2017\/03\/ISO80369-20_overriding.jpg\" alt=\"ISO80369_Resistance to overriding TEST METHOD\" width=\"580\" height=\"300\">\r\n","protected":false},"excerpt":{"rendered":"<p>Outline &#8220;PT-1946MC&#8221; can perform fitting and torsion stress test specified in common test method of &hellip; <a href=\"http:\/\/protec5461.co.jp\/protec\/?p=7464&#038;lang=en\">\u7d9a\u304d\u3092\u8aad\u3080 <span class=\"meta-nav\">&rarr;<\/span><\/a><\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_locale":"en_US","_original_post":"http:\/\/protec5461.co.jp\/protec\/?p=3943","footnotes":""},"categories":[1],"tags":[],"class_list":["post-7464","post","type-post","status-publish","format-standard","hentry","category-1","en-US"],"_links":{"self":[{"href":"http:\/\/protec5461.co.jp\/protec\/index.php?rest_route=\/wp\/v2\/posts\/7464","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/protec5461.co.jp\/protec\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/protec5461.co.jp\/protec\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/protec5461.co.jp\/protec\/index.php?rest_route=\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"http:\/\/protec5461.co.jp\/protec\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=7464"}],"version-history":[{"count":1,"href":"http:\/\/protec5461.co.jp\/protec\/index.php?rest_route=\/wp\/v2\/posts\/7464\/revisions"}],"predecessor-version":[{"id":7465,"href":"http:\/\/protec5461.co.jp\/protec\/index.php?rest_route=\/wp\/v2\/posts\/7464\/revisions\/7465"}],"wp:attachment":[{"href":"http:\/\/protec5461.co.jp\/protec\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=7464"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/protec5461.co.jp\/protec\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=7464"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/protec5461.co.jp\/protec\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=7464"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}